The City provides the following policies and standards as guidance for the design and installation of municipal infrastructure, as well as development applications.

The City reserves the right to update these documents, when necessary to account for changes to regulations, design practices and technologies. When revisions are made they will be posted to this website; it is the user’s responsibility to ensure they are using the current version.

Transportation

The City is developing a Transportation Guideline, scheduled to be issued in July 2016.

Roads Standards Drawings 

Roadworks (BSD-N2) Rev. #4

8.5 m Asphalt Road - 20.0 m Road Allowance, Urban - Residential (BSD-01) Rev. #4

8.0 m Asphalt Road - 26.0 m Road Allowance, Semi-Urban (BSD-02) Rev. #4

11.0 m Asphalt Road - 23.0 m Road Allowance, Urban (BSD-03) Rev. #4

11.0 m Asphalt Road - 26.0 m Road Allowance, Urban (BSD-04) Rev. #4

8.0 m Asphalt Road - 36.0 m Road Allowance, Semi-Urban (BSD-05) Rev. #4

14.0 m Asphalt Road - 26.0 m Road Allowance, Urban (BSD-06A) Rev. #4

14.0 m Asphalt Road - 30.0 m Road Allowance, Urban (BSD-06B) Rev. #4

18.0 m Asphalt Road - 30.0 m Road Allowance, Urban (BSD-07A) Rev. #4

18.0 m Asphalt Road - 36.0 m Road Allowance, Urban (BSD-07B) Rev. #4

25.0 m Asphalt Road - 40.0 m Road Allowance, Urban (BSD-07C) Rev. #2

Common Utility Trench - 20.0 m Road Allowance, Urban-Residential (BSD-42) Rev. #1

8.0 m Asphalt Road - 18.0 m Road Allowance Urban/Residential (BSD-43) Rev. #4

Driveway Entrance Detail (BSD-33) Rev. #3        

Industrial Urban Cul-de-sac (BSD-08) Rev. #1

Permanent Residential Cul-de-sac (BSD-09)

Temporary Residential Cul-de-sac (BSD-10) 

Offset Industrial Semi-Urban Cul-de-sac (BSD-11)

Typical Intersection Requirements (BSD-12)

Typical Industrial Intersection Semi-Urban - 18.0 m Radius - 36.0 m R.O.W./26.0 m R.O.W. (BSD-13)

Typical Industrial Intersection Semi-Urban - 18.0 m Radius - 26.0 m R.O.W./26.0 m R.O.W. (BSD-14)

Modified Rollover Curb (BSD-17) Rev. #2

Other Standards Drawing Index
Note: last revision was #12.2 and occurred in February 2006

Typical Title Pages (BSD-N1) Rev. #2

General Drawing Notes (BSD-N6) Rev. #3

Miscellaneous

Construction Entrance Mat (BSD-23D) Rev. #1

Topsoil or Spoil Pile Siltation Control (BSD-23E)

Typical Project Identification Sign (BSD-39) - Rev. #2

Unassumed Area Sign (BSD-40) - Rev. #2

Service Locations

Standard Residential Service Locations (BSD-25) Rev. #4

Standard Industrial/Commercial Service Locations (BSD-26) Rev. #1

Water Transmission & Distribution

Water Transmission and Distribution Policies and Design Guidelines

Approved Manufacturers
Water Transmission & Distribution Standards Drawings

General Notes – Watermain (BSD-500)  Rev. #2

Copper Water Service Connection Detail 19mm & 25mm Diameter  Sizes (BSD502)  Rev.#2

Copper Water Service Connection Detail 38mm & 50mm Diameter Sizes (BSD-503) 

25mm to 50mm Cross-Linked Polyethylene Water Service (BSD-504)

Typical Service Entry 100mm to 300mm Diameter Pipe (BSD-505)

Park Water Service and Irrigation Detail (BSD-506) Rev. #2

Standard Hydrant and Valve Installation (BSD-507)

Hydrant Platform Detail (BSD-508)

Pipe Bollard (BSD-509)

Typical Riser Detail (BSD-510)

Valve Stem Extension in Valve Box (BSD-511)

Typical Restrained Watermain Ductile or PVC (BSD-212)

Typical Cul-De-Sac Watermain Design (50mm Dia. Copper Looping) (BSD-513)

Typical Insulation Design (BSD-514)

Tracer Wire Detail (BSD-515)

50mm Blow Off Detail (BSD-516)

Direct Bury Air Release Valve For Watermain Up To 300mm Diameter (BSD-517)

Lowering Detail at New or Exist. Watermain Crossing Of New or Exist. Sanitary Sewer (BSD-518)

Lowering Detail of New or Existing Watermain Crossing New or Existing  Culvert, Storm Sewer or Ditch (BSD-519)

Support for Watermains Larger Than 300mm Diameter (BSD-520)

Watermain Crossing Detail – Railway (BSD-521)

Watermain Crossing Detail – Road (BSD-522)

Typical Epoxy Coated Steel Pressure Reducing Valve Chamber (BSD-523) 

Typical Precast Circular Chamber Details Over Existing Pipe (BSD-524)

Typical Two Piece Precast Rectangular Chamber Details for Watermains (BSD-525)

Flush Mounted Anode Station Test Station Installation (BSD-526)

Typical Thermit Weld (BSD-527)

Flushmount Anode Typical Test Station Wiring Arrangement (BSD-528)

Typical Zinc Reference Electrode (BSD-529)

Anode Installation Typical Single AugerSingle Excavation (BSD-530)

Typical 14.5kg High Potential Magnesium Anode (BSD-531)

Water Meter Installation Package (BSD-532)

Typical Meter Installation for Domestic Services Requiring By-Passes (BSD-533)

Sanitary Sewage Collection

Sanitary Sewage Collection System Policies and Design Guidelines

Sanitary Design Sheets 
Sanitary Standards Drawings

Sanitary Sewers (BSD-N3) Rev. #4, (BSD-N4) Rev. #2

Sanitary Sewer Design Sheet - Level 1 (SAN1)

Sanitary Sewer Design Sheet - Level 2 (SAN2)

Sanitary Sewer Design Sheet - Level 3 (SAN3)

Maintenance Hole and Catch Basin Grade Adjustment Units (BSD-41) Rev. #1

PVC Inside Drop Sewer Service Connection (BSD-15A) Rev. #3

PVC Inside Drop Sewer Maintenance Hole (BSD-15B) Rev. #4

Storm Drainage & Stormwater Management

Storm Drainage & Stormwater Management Policies & Design  Guidelines
Related documents: Appendix I

Storm Drainage & Stormwater General Drawings

Storm Sewers General Notes (BSD-N5) Rev. #4

Foundation Drain Outlet Sump Pump to Storm Sewer at Surface (BSD-75A)

Foundation Drain Outlet Sump Pump to Storm Sewer (BSD-75B)

Foundation Drain Outlet Sump Pump to Surface (BSD-76)

Outlet Structures  Typical Detail Wet Pond Facility With Maintenance Pipe (BSD-77)

Outlet Structure Typical Detail Wetland Facility Without Maintenance Pipe (BSD-78)

Temporary Outlet Structure Typical Detail (BSD-79)

SWM Grading and Water Level Criteria (BSD-80)

Forebay Dewatering Sump Detail (BSD-81)

Outlet Erosion Protection Typical Detail (BSD-82)

Stormwater Management Pond Warning Sign (BSD-83) 

Double Catch Basin, 45o Offset to Curb line (BSD-16) Rev. #1

Typical Single Gabion Drop (BSD-18) Rev. #1

Typical Granular; Erosion Control Device (BSD-23B) Rev. #2

Temporary Sediment Basin and Outlet Details (BSD-23C) Rev. #1

Maintenance Hole and Catch Basin Grade Adjustment Units (BSD-41) Rev. #1

Typical 100 mm Sub-Drain Detail (BSD-34) Rev. #1

Roadway Illumination & Traffic Signals

Roadway Illumination Policies and Design Guidelines

Approved Manufacturers
Roadway Illumination Standards Drawings

Roadway Lighting Duct Installation at Utility Crossing (BSD-800)

Roadway Lighting Duct Installation in Existing Paved Area (BSD-801)

Underground Rigid Duct Connection at Concrete Structure (BSD-802)

Electrical Vaults Entry of Encased Ducts (BSD-803)

Electrical Handhole General Installation Requirements (BSD-804)

Electrical Handhole Entry of Direct Buried and Encased Ducts (BSD-805)

Electrical Handhole Precast Concrete – 600mm x 600mm (BSD-806)

Prefabricated Service Box Assemblies (BSD-807)

Typical Loop and Street Lighting Junction Box (BSD-808)

Electrical Handhole Installation in Slope (BSD-809)

Supply Control Cabinet Installation Overhead Services Bottom Entry (BSD-810)

LS3M Supply Control Cabinet Assembly Type 3M 12O/240V, 100A, 1-Phase, 3-Wire (BSD-811)

LS3M Supply Control Cabinet Assembly Type 3M Equipment List (BSD-812)

LS3M Supply Control Cabinet Assembly Type 3M Enclosure (BSD-813)

LS3M Supply Control Cabinet Assembly Type 3M Dead Front Panel (BSD-814)

LS3M Supply Control Cabinet Assembly Type 3M Door Latch (BSD-815)

LS3M Supply Control Cabinet Assembly Type 3M Instrument Layout (BSD-816)

Power Supply (42") Pedestal and Base Assembly (BSD-817)

Galvanized Octagonal Steel Pole, Base Mounted (BSD-818)

Pole Mounting Details for Base Mounted Metal Pole (BSD-819)

Metal Lighting Pole Base Mounted (BSD-820)

Concrete Footing for Base Mounted Pole (BSD-821)

Aluminum Combination and Streetlight Pole Base Mounted (BSD-822)

Anchorage Assembly (BSD-823)

Local Grading at Pole Foundations (BSD-824)

Pole Wiring Diagram 12DV System (BSD-825)

Decorative Concrete Pedestrian Pole, Direct Buried (5.49m) (BSD-826)

Decorative Concrete Pedestrian Pole, Direct Buried (5.49m) (BSD-827)

Decorative Concrete Pole, Direct Buried (8.38m) (BSD-828)

Decorative Concrete Pole, Direct Buried (8.38m) (BSD-829)

Installation of Direct Buried Poles in Slopes (BSD-830)

Traffic Signals Standards Drawings

460mm Dia. Pole Base to fit 3.7m POWCO Steel Pole (BSD-TS-1A)

600mm Dia. Pole Base to fit 6.1m POWCO Steel Pole in Median Island (BSD-TS-1B)

762mm Dia. Pole Base to fit 6.1m, 7.3m & 9.1m POWCO Steel Pole (BSD-TS-1C)

Typ. Traffic Signal Controller Concrete Pad Detail (BSD-TS-2)

Remote Antenna Mounting Detail (BSD-TS-3)

Aerial Cable Attachment Detail (BSD-TS-4)

Traffic Signal Equipment on Steel Poles (Buried Installation) (BSD-TS-5)

Mounting Details for Controller Cabinet on Wood or Concrete Poles (BSD-TS-6)

Traffic Signal Head on Vertical Bracket Mounting Detail (BSD-TS-7)

Elevator Plumbizer Attachment Detail (BSD-TS-8)

Temporary Mast Extension Detail (BSD-TS-9)

Integrated Dome Closed Circuit T.V. Camera Mounting Detail (BSD-TS-10)

Typical Traffic Signal Wiring for Pedestrian Equipment (BSD-TS-11)

Audible Pedestrian Signal Mounting Detail (BSD-TS-12)

Installation Detail for Optical Pre-emption Detector (BSD-TS-13)

Typical Buried Power Supply Mounting Detail (BSD-TS-14A)

Typical Aerial Power Supplies (BSD-TS-14B)

Parks

Parks Standards Drawings
Signs

Standard Park Sign (BSD-1300)

Park Safety and Regulations Sign (BSD-1301)

Future Open Space – Park Block Sign for Development Sites (BSD-1302)

Site Alteration Notification Template (BSD-1237)

Fences & Gates

Acoustic Fence (BSD-1200)

Acoustic Fence Slope Accommodation (BSD-1201)

Acoustic Gate Side Lot Return (BSD-1202)

Acoustic Fence Masonry Column (BSD-1203)

Residential to Residential Reverse Lot Frontage Fence (BSD-1204)

Board on Board Residential to Residential Fence (BSD-1205)

Overlapping Board Residential to Residential Fence (BSD-1206)

Residential to Residential Board Fence Slope Accommodation (BSD-1207)

Non-Residential to Residential Fence (BSD-1208)

1.25m Chain Link Frontage Return Fence (BSD-1209)

1.52m Chain Link Parking Fencing (BSD-1210)

1.80m Chain Link Stormwater Facility Fencing (BSD-1211)

Tennis Court Chain Link Fence (BSD-1212)

Typical Walkway and Barrier (BSD-1215)

Vehicular Control Gate (BSD-1216)

Timber Bollard Detail (BSD-1217)

Siltation Control Fencing (BSD-1233)

Play Areas, Trails, Pathways & Walkways

Typical Play Area and Walkway Layout/Section (BSD-1270)

Typical Play Area Curb and Drainage Detail (BSD-1271)

Typical Park Walkway Section with Centre Crown (BSD-1272)

Typical Park Walkway Section with Cross Slope (BSD-1273)

Park Walkway Lighting Assembly and Ductbank (BSD-1350)

Typical Park Walkway and Morality Lighting Electrical Pedestal  (BSD-1351)

Trail and Pathway Construction Matrix  (BSD-1274)

Typical Streetscape Pavingstone Detail  (BSD-1360)

Irrigation

Pipe Wire Trenching for Irrigation (BSD-1285)

Manual Drain Installation for Irrigation (BSD-1286)

Sports Fields & Courts

Baseball

Baseball Infield Layout with Backstop and Fencing (BSD-1260)

Baseball Field Layout (BSD-1261)

Baseball Field Preferred Grading (BSD-1262)

Baseball Backstop Detail (BSD-1263)

Baseball Pitching Mound and Infield Mix Detail (BSD-1264)

Basketball

Basketball Full Court Layout (BSD-1291)

Basketball Court Profile (BSD-1292)

Basketball Net Assembly Installation (BSD-1293)

Basketball Half Court Layout (BSD-1294)

Soccer

Senior Soccer Field (Unlit) (BSD-1280)

Senior Soccer Field Grading (BSD-1281)

Senior Soccer Field Irrigation Schematic (BSD-1282)

Senior Soccer Field Irrigation Notes (BSD-1283)

Softball

Softball Infield Layout with Backstop and Fencing (BSD-1255)

Softball Field Layout (BSD-1256)

Softball Field Preferred Grading (BSD-1257)

Softball Backstop Detail (BSD-1258)

Tennis

Tennis Court Chain Link Fence (BSD-1212)

Tennis Court Layout (BSD-1250)

Tennis Court Surface and Net Post Detail (BSD-1251)

Trees & Planting Zones

General Park Planting Notes (BSD-1320)

Tree Removal Notification Template (BSD-1230)

Tree Preservation Area Template (BSD-1231)

Tree Preservation Fencing (BSD-1232)

Limit of Tree Protection for Activities on Municipal Right-of-Ways (BSD-1234)

Limit of Tree Preservation for Development Approvals (BSD-1235)

Tree Hoarding Detail for Activities on Municipal Right-of-Ways (BSD-1236)

Deciduous Tree Planting Detail (BSD-1310)

Deciduous Tree Planting on Slope (BSD-1311)

Coniferous Tree Planting Detail (BSD-1312)

Coniferous Tree Planting on Slope (BSD-1313)

Container Grown Shrub Planting Detail (BSD-1314)

Street Tree Layout (BSD-1315)

Streetscape Boulevard Tree Planting Notes (BSD-1321)

Live Staking Planting Detail (BSD-1317)

Stormwater Planting Zone Composition (BSD-1318)

Looks like your screen is a bit too small